Skip to content

Configuring Your System

Desktop shortcuts should be created using the Windows Shortcut Wizard.

Right mouse click on your desktop and select New, then select Shortcut.

The Target value must point to where the Basic executable is installed.

  • On all platforms the default is C:\Program Files (x86)\Tbsc.

The Start In value must point to where Dictionary-IV/OPENworkshop is installed.

  • On Windows desktop workstations or Windows Server class machines the default is C:\ProgramData\Thoroughbred Software\Tbsc.

Edit the IPL file used for TS Environment for Windows (normally IPLINPUT.TXT) and make the changes described below. The IPLINPUT file is a standard text file that can be modified using notepad.exe or any windows text editor. For more information on the IPLINPUT file, please refer to the Thoroughbred Basic Customization and Tuning Guide.

Change the PTN statement to set a minimum partition of 300000. The PTN statement should appear as follows:

PTN 1,300000

The number of file table entries is set in the operating system as well as in the CNF statement of the TS Environment for Windows IPLINPUT file.

In most cases, it is recommended that you change the CNF statement to set a minimum of 40 for the open file table entries. The CNF statement should look like this:

CNF 1,6,1,40

This section describes how to perform system administration functions such as adding directories or printers to TS Environment for Windows. For more information see the Basic Customization and Tuning Guide.

This section describes how to make Microsoft Windows directories accessible to TS Environment for Windows.

  • If the directory does not exist, create it in Microsoft Windows using the MKDIR command.

  • Modify the IPLINPUT file using a text editor such as EDIT.

    CNF 1,6,1,40Increase the number of devices in the CNF line. If you add one DEV line, change the 6 to a 7.
    PTN 1, 300000
    DEV D0,1,,,,,,IDL4In the following three DEV lines, D0, D1, and D9 specify the number of each available directory.
    DEV D1,1,,,,,,WORKInsert a DEV line after this one. The format is DEV Dn,1,,,,,,[d:][path]. Example: DEV D2,1,,,,,,C:\FILES
    DEV D9,1,,,,1,,
    DEV LP,4,,,,,,LPT1
    DEV T0,5,,,,,,CONIn this DEV line, 5 specifies Thoroughbred Basic Windows (TCONFIGW) and 7 specifies that Thoroughbred Basic Windows will not be used (TCONFIG8).
    DEV T1,7,,,,,,TTY1
    IPL 1,2,T0,ID
    END

Save and exit, then re-execute TS Environment for Windows.

This section describes how to make Microsoft Windows system printers accessible to TS Environment for Windows.

  • Install and set up printers.

  • Modify the IPLINPUT file using a text editor such as EDIT.

    CNF 1,6,1,40Increase the number of devices in the CNF line. If you add one DEV line, change the 6 to a 7.
    PTN 1, 300000
    DEV D0,1,,,,,,IDL4
    DEV D1,1,,,,,,WORK
    DEV D9,1,,,,1,,
    DEV LP,4,,,,,,LPT1The two-character printer-ID must be either LP, as it is here, or P1 through Px, where x is any alphanumeric character. Insert a DEV line after this one.

    DEV RS,4,,,,,,NULL Example DEV line for TS ReportServer
    DEV RC,4,,,,,,NULL Example DEV line for Report-IV to PDF

    DEV T0,5,,,,,,CON
    DEV T1,7,,,,,,TTY1
    IPL 1,2,T0,ID
    END

Save and exit, then re-execute TS Environment for Windows.

Using the previously defined IPLINPUT file, this section shows an example of a modified file.

  • Modify the IPLINPUT file using a text editor such as EDIT.

    CNF 1,9,1,40The total number of DEV lines is 9.
    PTN 1, 300000
    DEV D0,1,,,,,,IDL4
    DEV D1,1,,,,,,WORK
    DEV D2,1,,,,,,TESTThis directory specification has been added.
    DEV D3,1,,,,,,C:\DATA\FILESThis directory specification has been added.
    DEV D9,1,,,,1,,
    DEV LP,4,,,,,,LPT1This printer specification has been added.
    DEV P1,4,,,,,,LPT2
    DEV RS,4,,,,,,NULL
    DEV RC,4,,,,,,NULL
    DEV T0,5,,,,,,CON
    DEV T1,7,,,,,,TTY1

    IPL 1,2,T0,ID

    END

From the TS Environment for Windows Installation Guide, version 8.9.1. Open this page in the PDF